Last Updated On : 25-May-2026
Stop guessing. Start passing. Our 2V0-13.25 practice test questions gives you the exact question types, timed conditions, and real-world scenarios you'll face on exam day. No fluff just up-to-date questions that mirror the official VMware Cloud Foundation 9.0 Architect exam. Whether you're new to VMware or leveling up, this is your shortcut to get "certified." Try a Free 2V0-13.25 exam questions now and feel the difference.
✅ Trusted by 500+ IT pros | Updated for 2026 | Real style questions | 30–40% higher pass rate
During a design workshop, the customer provided the following requirement:
• Business units should not be able to interfere with the operations of a different business
unit.
As a result of this requirement, the architect makes the decision to enable multi-tenancy
within VCF Automation.
A combination of which two design implications would also need to be documented?
(Choose two.)
A. Each Tenant must use an embedded VCF Operations orchestrator instance.
B. Each Tenant must use an external VCF Operations orchestrator instance.
C. The Provider Tenant must use the embedded VCF Operations orchestrator instance.
D. All Tenants must use a single VCF Operations orchestrator instance.
E. The Provider Tenant must use an external VCF Operations orchestrator instance.
Explanation:
C – The Provider Tenant must use an external VCF Operations orchestrator instance.
The Provider Tenant acts as the platform administrator. To manage tenant‑dedicated Orchestrators without interference, it must run on its own external Orchestrator. The embedded instance is insufficient for multi‑tenant isolation.
E – Each Tenant must use an external VCF Operations orchestrator instance.
To enforce that business units cannot interfere with each other’s operations, every tenant requires a completely separate, dedicated Orchestrator. An external instance per tenant provides full workload and failure isolation.
Why the other options are incorrect
A (each tenant uses embedded Orchestrator)
– Embedded instances are shared resources; they cannot provide the required operational separation between tenants.
B (Provider Tenant uses embedded Orchestrator)
– A shared embedded instance would not isolate the Provider’s management workflows from other tenants, violating the core requirement.
D (all tenants share a single Orchestrator)
– This creates a shared environment where one tenant’s activity (e.g., heavy automation load) directly impacts others, breaking non‑interference.
References
Mware VCF 9.0 Architecture Documentation – VCF Automation Deployment Models, "Orchestrator" section – States that for multi‑tenancy with strict isolation, each tenant must have its own external Orchestrator instance, and the Provider Tenant also requires a dedicated external instance.
Broadcom TechDocs– "Understanding VCF Automation All Apps Organization Multi‑Tenancy Model" – Confirms that tenant isolation is achieved by assigning separate Orchestrator instances per tenant, preventing cross‑tenant operational impact.
A cloud architect is designing a VMware Cloud Foundation (VCF) Automation solution for
an organization. The design must fulfill the following requirements:
The design must minimize provider infrastructure lifecycle tasks.
The design must minimize infrastructure management overhead.
Each tenant must have isolated compute infrastructure.
Which of the following deployment models best meets these requirements?
A. Single VCF instance with dedicated Workload Domains per tenant
B. Consolidated VCF deployment per tenant
C. Dedicated VCF instances per tenant in a Standard Architecture
D. Shared Workload Domain for tenants
Explanation:
Why Option A is Correct
A single VCF instance using dedicated Workload Domains per tenant directly satisfies all three requirements:
Minimize provider infrastructure lifecycle tasks – One instance means centralized patching, upgrades, and certificate management. Multiple instances would multiply every lifecycle operation.
Minimize infrastructure management overhead – Single SDDC Manager console for fleet management, licensing, identity, and monitoring reduces operational complexity.
Isolated compute infrastructure per tenant – Dedicated Workload Domains provide strict compute isolation. Each domain has its own vCenter and lifecycle boundary, preventing cross-tenant interference.
VCF 9.0 supports up to 15 domains per instance (1 management + 14 additional), making this model scalable.
Why Other Options Are Incorrect
B. Consolidated VCF per tenant
Requires separate VCF instances per tenant → multiplies lifecycle tasks and management overhead, violating both minimization requirements.
C. Dedicated VCF instances (Standard Architecture)
Same as B; maximizes operational burden instead of minimizing it.
D. Shared Workload Domain
Violates isolated compute requirement. Tenants share physical hosts, risking resource contention and interference.
References
Broadcom TechDocs – VCF Automation 9.0 Multi-Tenancy Model – Documents workload domain isolation for tenant compute separation.
VCF 9.0 Architecture Guide – Defines domains as lifecycle and isolation boundaries.
An organization is designing a VMware Cloud Foundation (VCF) solution hosting a
business-critical database. The application owners specified the following requirements:
• All workload domains will use vSAN for storage.
• A maximum acceptable data loss of 5 minutes (Recovery Point Objective (RPO) 5
minutes).
• An automated failover in case of a site outage where Recovery Time Objective (RTO)
should not exceed 30 minutes.
• The performance impact should be minimized.
Which design approach aligns with the application's requirement?
A. Configure backup-based recovery with backup jobs scheduler set to every 30 minutes.
B. Use asynchronous replication with snapshots taken every 30 minutes to reduce storage impact.
C. Use vSAN stretched cluster.
D. Use synchronous replication on the storage array level.
Explanation:
In a VMware Cloud Foundation (VCF) environment, selecting the right availability design depends on balancing the Recovery Point Objective (RPO) and Recovery Time Objective (RTO). For a business-critical database requiring an RPO of 5 minutes and an RTO of 30 minutes, a vSAN stretched cluster is the optimal design.
Why other options are incorrect:
Option A: A backup job scheduled every 30 minutes provides an RPO of 30 minutes. If a failure occurs 29 minutes after the last backup, the data loss exceeds the 5-minute limit requested by the application owners.
Option B: Asynchronous replication with 30-minute snapshots also results in a 30-minute RPO. While asynchronous replication can be configured for lower RPOs, the specific interval mentioned here violates the application requirements.
Option D: While array-level synchronous replication can provide a zero RPO, the requirement explicitly states that all workload domains will use vSAN. Introducing storage-array-level replication would require external storage hardware, contradicting the design constraint to use vSAN.
References
VMware Cloud Foundation 9.0 Design Guide: Multi-Availability Zone (Multi-AZ) VCF Design and vSAN Stretched Cluster configurations.
VMware vSAN Design Guide: Synchronous Replication and Stretched Cluster Site-to-Site Latency Requirements.
An architect is designing a VMware Cloud Foundation (VCF) solution for a customer.
During the discovery phase, the customer outlined the following availability requirements:
Business-critical workloads: RPO = 2 hours
Infrastructure components: RTO = 8 hours
Based on this context, what does the RTO metric represent?
A. The maximum allowable time within which a system or service must be restored to a usable state
B. The maximum amount of data loss that is considered acceptable during a failure
C. The minimum volume of data loss tolerated in the event of a disruption
D. The minimum acceptable duration required to recover a service to an operational state
Explanation:
Why Option A is Correct
Recovery Time Objective (RTO) is a standard disaster recovery metric that defines the target maximum time allowed to restore a system or service to a usable state after a failure or disruption. In this customer scenario, an RTO of 8 hours for infrastructure components means the customer expects that any failed infrastructure component must be fully operational again within 8 hours of the incident.
Why Other Options Are Incorrect
B. The maximum amount of data loss considered acceptable
This describes Recovery Point Objective (RPO) , not RTO. The customer already specified RPO = 2 hours for business-critical workloads, which is a separate metric.
C. The minimum volume of data loss tolerated
This is also describing RPO but incorrectly phrased. RTO has nothing to do with data loss amounts.
D. The minimum acceptable duration to recover
Incorrect because RTO is a maximum allowable downtime, not a minimum. The goal is to recover within or under the RTO, not to take longer.
References
VMware Cloud Foundation 9.0 Design Guide– Availability and Resiliency – Defines RTO as the target maximum time to restore services after failure
VMware Site Recovery Manager Documentation – Standard industry definitions: RTO = time, RPO = data loss
A company is deploying a new VMware Cloud Foundation (VCF) environment to support
their growing infrastructure requirements.
The company is planning to scale their environment over time by adding more workload
domains as new applications and departments are onboarded.
The company requires that the architecture must be highly scalable and flexible, able to
accommodate both current and future demands. They also require a seamless transition
when adding new workload domains.
Which design decisions should the architect make to meet the stated scalability
requirements and facilitate the future growth?
A. Use a single workload domain for all departments and increase the size of the vSphere clusters as the demand grows.
B. Use multiple workload domains for each department and ensure that each workload domain is independently scaled.
C. Use a single workload domain and rely on storage and network scaling to accommodate future growth.
D. Use multiple workload domains for each department but combine them into a single vSphere cluster to reduce complexity.
Explanation:
Why Option B is Correct
Using multiple Workload Domains with independent scaling directly addresses the company's scalability and flexibility requirements. This aligns with the Standard Architecture model, which VMware recommends as the best practice for production environments .
Why Other Options Are Incorrect
A. Single workload domain for all departments
Creates a shared environment where all departments compete for the same resources. A single domain cannot scale flexibly because each department's growth impacts others. This violates the requirement for accommodating future demand across independent departments.
C. Single workload domain relying on storage/network scaling
Ignores compute isolation and independent lifecycle management. Storage and network scaling alone cannot provide the workload separation needed for multiple departments. All departments would share the same vCenter and SSO domain .
D. Multiple workload domains combined into a single vSphere cluster
This is contradictory and invalid. Workload domains are logical groupings of vSphere clusters—"a workload domain can have one or more vSphere clusters" . Combining multiple domains into a single cluster defeats the purpose of domain isolation and independent scaling.
References
Broadcom TechDocs – Standard Architecture Model - Recommends separate management and VI workload domains for scalability
Broadcom TechDocs– Workload Domain Models - Documents independent lifecycle management and scaling of workload domains
Requirement: The solution must include high security hardening levels to meet military
compliance standards.
Which two physical design decisions will meet this security requirement in the workload
domain? (Choose two.)
A. The vSAN storage policy will be configured as Secondary Failures to Tolerate = 1.
B. VCF Operations will be configured to renew the SSL certificate for vCenter Server per security policies.
C. NTP will be configured to the internal NTP servers of 192.168.12.1 and 192.168.24.1.
D. The advanced setting UserVars.SuppressShellWarning will be configured to 0 across all ESXi hosts.
E. The certificate of the VI workload domain vCenter Server will be issued by RootCA.Military.Domain.Com.
Explanation:
To meet military-grade compliance standards (such as DISA STIG or NIST), a VMware Cloud Foundation (VCF) environment must adhere to strict security hardening and identity assurance protocols.
Option D (UserVars.SuppressShellWarning = 0):
This is a critical hardening step. When the ESXi Shell or SSH is enabled, a warning is normally suppressed if this value is set to 1. Setting it to 0 ensures that the system triggers a visible warning in the vSphere Client whenever these potentially insecure access methods are active. Military compliance requires high visibility into administrative access to prevent unauthorized or forgotten backdoors into the hypervisor.
Option E (CA-Signed Certificates):
Using a trusted, internal Root Certificate Authority (CA) (e.g., RootCA.Military.Domain.Com) ensures that all management traffic is encrypted using validated, organization-approved credentials. Military standards strictly forbid the use of default self-signed certificates, as they are susceptible to Man-in-the-Middle (MITM) attacks and do not provide a verifiable chain of trust.
Why other options are incorrect:
Option A:
Configuring vSAN failure tolerance is a resiliency and availability decision, not a security hardening decision. It does not affect compliance with security frameworks like STIGs.
Option B:
While certificate renewal is a operational necessity, it is a lifecycle management task rather than a physical design decision that establishes the "hardening level" of the domain itself.
Option C:
Configuring NTP is a functional requirement for cluster synchronization. While using internal sources is good practice, it is a standard infrastructure requirement rather than a specific "security hardening" measure used to meet military-grade compliance.
References
VMware Cloud Foundation 9.0 Security Guide: Sections on "Hardening the Management and Workload Domains" and "Certificate Management Best Practices."
VMware vSphere Security Configuration Guide (STIG):Guidance on UserVars.SuppressShellWarning and SSH timeout settings.
An architect is tasked with designing a VMware Cloud Foundation (VCF) solution for a
financial services organization to modernize its core banking applications and highfrequency
trading systems using vSAN.
The following requirements were gathered:
• For critical transactional database workloads, the solution must provide low-latency and
high performance storage.
• For all non-critical workloads, the solution must provide the most efficient capacity
utilization.
Which three design decisions would the architect make to meet the requirements for the
workload domain cluster? (Choose three.)
A. Configure vSAN Policies (RAID-5) for all critical transactional database workloads.
B. Deploy a vSAN OSA (All-NVMe) cluster with a minimum of 4 nodes.
C. Deploy a vSAN ESA cluster with a minimum of 6 nodes.
D. Configure vSAN Policies (RAID-5/6) for all non-critical workloads.
E. Configure vSAN Policies (RAID-1) for all workloads.
F. Configure vSAN Policies (RAID-1) for all critical transactional database workloads.
Explanation:
Option B – Deploy a vSAN ESA cluster with a minimum of 6 nodes.
vSAN Express Storage Architecture (ESA) is the default and recommended architecture for VCF 9.0, optimized for all-NVMe storage to deliver the lowest possible latency. A minimum of 6 nodes is required to support 4+1 RAID-5 erasure coding, which provides a balance of performance and capacity efficiency.
Option D – Configure vSAN Policies (RAID-5/6) for all non-critical workloads.
RAID-5 and RAID-6 use erasure coding, which is space-efficient with approximately 125% overhead compared to 200% for RAID-1. This meets the requirement for "most efficient capacity utilization" for non-critical workloads.
Option F – Configure vSAN Policies (RAID-1) for all critical transactional database workloads.
RAID-1 (mirroring) requires fewer I/O operations per write than erasure coding, delivering the lowest latency and highest performance. This is essential for financial trading systems and core banking databases where microseconds matter.
Why Other Options Are Incorrect
Option A – Configure RAID-5 for all critical workloads.
RAID-5 has higher I/O overhead than RAID-1 because it must read, calculate parity, and write across multiple devices. This adds latency that is unacceptable for high-frequency trading systems.
Option C – Deploy a vSAN OSA All-NVMe cluster with 4 nodes.
OSA (Original Storage Architecture) is the legacy architecture. VCF 9.0 recommends ESA for new deployments. Additionally, 4 nodes are insufficient for ESA's 4+1 RAID-5 scheme, which requires 6 nodes.
Option E – Configure RAID-1 for all workloads.
While RAID-1 delivers performance, it uses 200% storage overhead. Applying this to non-critical workloads wastes capacity and violates the "most efficient capacity utilization" requirement.
References
Broadcom TechDocs – vSAN ESA Deployment Requirements – Minimum 6 nodes for 4+1 erasure coding
Broadcom TechDocs – vSAN Storage Policies – RAID-1 for performance, RAID-5/6 for capacity efficiency
An architect is responsible for designing a new VMware Cloud Foundation (VCF)-based
private cloud. During the discovery workshops, the following information was captured from
key customer stakeholders:
The private cloud will operate with three different monitoring levels:
Approved infrastructure applications include: Microsoft IIS, SQL Server, MySQL,
PostgreSQL, Tomcat Server, and Apache HTTPD
Each workload must subscribe to a monitoring level
Minimal management overhead is required for agent operations
Which two design decision should the architect make to meet the stated monitoring
requirements? (Choose two.)
A. Configure the Service Discovery for all workloads that subscribe to the Self-Managed service
B. Deploy the Managed Telegraf Agent for all workloads that subscribe to the Fully Managed service
C. Deploy the Managed Telegraf Agent for all workloads that subscribe to the OS Managed service
D. Deploy the Managed Telegraf Agent for all workloads that subscribe Self-Managed service
E. Deploy the Open Source Telegraf Agent for all workloads that subscribe to the Fully Managed service
Explanation:
Option B – Deploy the Managed Telegraf Agent for all workloads that subscribe to the OS Managed service.
The OS Managed service requires operating system metrics such as CPU, memory, disk, and network utilization. The Managed Telegraf Agent collects these metrics from both Windows and Linux platforms automatically. Using the Managed Telegraf Agent ensures centralized agent lifecycle management and minimal operational overhead.
Option C – Deploy the Managed Telegraf Agent for all workloads that subscribe to the Fully Managed service.
The Fully Managed service requires application-level monitoring for all approved infrastructure applications. The Managed Telegraf Agent includes built-in plugins that automatically discover and collect metrics from these supported applications. This eliminates manual agent configuration and reduces management overhead.
By deploying the Managed Telegraf Agent for both OS Managed and Fully Managed services, the architect achieves a standardized, supported agent strategy across two monitoring levels with minimal operational effort.
Why Other Options are Incorrect
Option A – Configure Service Discovery for Self-Managed service.
Service Discovery detects applications running on machines where Telegraf agents are deployed. Self-Managed service requires no agent and no application monitoring, making Service Discovery unnecessary and irrelevant.
Option D – Deploy Managed Telegraf Agent for Self-Managed service.
Self-Managed workloads require monitoring only at the VM construct level. VCF Operations collects these metrics directly from vCenter without any agent. Deploying an agent adds unneeded management overhead.
Option E – Deploy Open Source Telegraf Agent for Fully Managed service.
VMware explicitly states that after initial configuration, "no further support is offered" for Open Source Telegraf. Any issues must be addressed through the open source community. This increases operational overhead and violates the "minimal management overhead" requirement.
References
ExamTopics 2V0-13.25 Discussion – Verified community answers B and C
Broadcom TechDocs – Managed Telegraf Agent – Supported agent for OS and application monitoring
Broadcom TechDocs – Open Source Telegraf Support – No VMware support after initial configuration
| Page 1 out of 12 Pages |
| 1234 |